Rainscreen Fire Barrier
FIREZERO Series 1080 Rain screen Vertical fire closure consists of a carrier of medium density mineral wool encapsulated in Class 0 Foil. A galvanised steel fixing strap is with the product to prevent slippage.
Download Datasheet: Rainscreen Fire Barrier.pdf
FIREZEROSeries 1080 is designed to go between the external rain screen cladding and the internal wall structure to create a fire break vertically, normally level with the internal walls. The use of a full fill vertically FIREZEROSeries 1080 also achieves the acoustic requirements of Document E (2003 edition) of the building regulations. Generally an air gap is not needed vertically meaning the product works under compression filling the vertical void creating an economical solution. Although fixed by compression a bracket must be used. The system is designed to be used with our horizontal systems regardless of air gap requirements. (See data sheet 103, 105 and 728).